Showing posts with label germany. Show all posts
Showing posts with label germany. Show all posts

Saturday, October 8, 2016

New Chimeric Porcine Coronavirus in Swine Feces Germany 2012 Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC

New Chimeric Porcine Coronavirus in Swine Feces Germany 2012 Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC


New Chimeric Porcine Coronavirus in Swine Feces, Germany, 2012 - Volume 22, Number 7—July 2016 - Emerging Infectious Disease journal - CDC



Volume 22, Number 7—July 2016

Letter

New Chimeric Porcine Coronavirus in Swine Feces, Germany, 2012

On This Page

  • Letter
  • Suggested Citation

Figures

  • Figure

Technical Appendicies

Downloads

  • PDF[464 KB - 2 pgs]
  • RIS[TXT - 2 KB]
Suggested citation for this article
To the Editor: Porcine epidemic diarrhea virus (PEDV) and transmissible gastroenteritis virus (TGEV) can cause severe enteritis in pigs accompanied by diarrhea, vomiting, and dehydration. Clinical signs are most prominent in young suckling pigs, in which high mortality rates are common. As seen in recent porcine epidemic diarrhea outbreaks in the United States and Asia, the effect on the pig industry can be tremendous.
Recently, Boniotti et al. (1) reported detection and genetic characterization of swine enteric coronaviruses (CoVs) circulating in Italy during 2007–2014. Characterization was based on sequencing and phylogenetic analyses of spike genes of TGEV and PEDV isolates. This study also reported a new recombinant CoV strain with a TGEV backbone and a PEDV spike gene (SeCoV/Italy/213306/2009; KR061459), which was identified as a swine enteric CoV (SeCoV). This chimeric virus presumably resulted from a recombination event.
Thumbnail of Electron micrograph of a new chimeric swine enteric coronavirus (SeCoV/GER/L00930/2012), Germany, 2012. Scale bar indicates 100 nm.
Figure. Electron micrograph of a new chimeric swine enteric coronavirus (SeCoV/GER/L00930/2012), Germany, 2012. Scale bar indicates 100 nm.
Accompanying a study of recent porcine epidemic diarrhea cases in Germany caused by a new PEDV Indel strain (2), we retrospectively analyzed fecal samples from pigs that showed typical clinical symptoms of a PEDV infection. The sample set included fecal material collected from a farm in southern Germany on which an episode of diarrhea among pigs occurred in 2012. This material was shown by electron microscopy to contain CoV-like particles (Figure), but showed negative results by reverse transcription PCRs specific for the PEDV nucleocapsid gene.
Subsequent metagenomic analyses resulted in the full-genome sequence of a swine enteric CoV (SeCoV/GER/L00930/2012). We found a sequence showing high similarity (99.5% identity) with the TGEV/PEDV recombinant reported by Boniotti et al. (1). Network analysis of complete genome sequences of similar CoVs underline the chimeric nature of the genome between TGEV and PEDV genome sequences (Technical Appendix[PDF - 386 KB - 1 page] Figure, panel A). The chimeric nature of the virus strain was confirmed by RT-PCR with primers spanning possible recombination sites and analysis of overlapping reads from next-generation sequencing.
Annotation of the sequence of SeCoV/GER/L00930/2012 performed on the basis of SeCoV/Italy/213306/2009 identified a similar putative coding sequence with a TGEV backbone and a spike coding sequence similar to that for PEDV (Technical Appendix[PDF - 386 KB - 1 page] panel B). Downstream of the spike protein–coding open reading frame (ORF), an additional hypothetical ORF was identified in both SeCoV sequences. The coded amino acid sequences (27 aa in the virus from Germany and 30 aa in the virus from Italy) resembled an N- and C-terminally truncated TGEV nonstructural protein 3a. The difference of 3 aa between the 2 strains is the result of a 10-bp deletion at the 3?-end of the hypothetical ORF, which shifted the stop 3 codons to the 5?- end (Technical Appendix[PDF - 386 KB - 1 page] Figure, panel B) in SeCoV/GER/L00930/2012. This deletion is apparently located within the potential 3? recombination site (Technical Appendix[PDF - 386 KB - 1 page] Figure, panel B).
It is tempting to speculate that SeCoV/Italy/213306/2009 is a precursor of SeCoV/GER/L00930/2012, and that other members of this novel genotype are still undetected. These viruses might be targets of secondary mutation and recombination events. Therefore, more chimeric CoVs should be identified to determine the potential origin of the recombination event.
In conclusion, we detected an enteric CoV that resembled the TGEV/PEDV chimeric virus reported by Boniotti et al. (1). Although these findings support the notion that CoV genomes are subject to mutations and recombination events, problems in disease diagnosis can be foreseen. In countries where porcine epidemic diarrhea, transmissible gastroenteritis, or both of these diseases are reportable, correct diagnosis and reporting might be difficult. Thus, diagnosticians should be aware of possible recombinants of swine CoVs. Diagnostic problems can be prevented by use of a double-check strategy with techniques specific for different genome regions. Apart from diagnostic obstacles, the effect of virus recombinations in terms of virulence and organ tropism is unknown and needs further investigations.
Valerij Akimkin1, Martin Beer1Comments to Author , Sandra Blome1, Dennis Hanke1, Dirk Höper1, Maria Jenckel1, and Anne Pohlmann1
Author affiliations: Chemical and Veterinary Investigations Office Stuttgart, Fellbach, Germany (V. Akimkin); Friedrich-Loeffler-Institut, Greifswald–Insel Riems, Germany (M. Beer, S. Blome, D. Hanke, D. Höper, M. Jenckel, A. Pohlmann)

References

  1. Boniotti MB, Papetti A, Lavazza A, Alborali G, Sozzi E, Chiapponi C, Porcine epidemic diarrhea virus and discovery of a recombinant swine enteric coronavirus, Italy. Emerg Infect Dis. 2016;22:83–7 . DOIPubMed
  2. Hanke D, Jenckel M, Petrov A, Ritzmann M, Stadler J, Akimkin V, Comparison of porcine epidemic diarrhea viruses from Germany and the United States, 2014. Emerg Infect Dis. 2015;21:493–6 . DOIPubMed

Figure

  • Figure. Electron micrograph of a new chimeric swine enteric coronavirus (SeCoV/GER/L00930/2012), Germany, 2012. Scale bar indicates 100 nm.

Technical Appendix

  • . Analysis of a new chimeric swine enteric coronavirus (SeCoV/GER/L00930/2012), Germany, 2012.  386 KB
Suggested citation for this article: Akimkin V, Beer M, Blome S, Hanke D, Höper D, Jenckel M, et al. New chimeric porcine coronavirus in swine feces, Germany, 2012 [letter]. Emerg Infect Dis. 2016 Jul [date cited]. http://dx.doi.org/10.3201/eid2207.160179
DOI: 10.3201/eid2207.160179


1All authors contributed equally to this article.

download now

Read more »

Friday, September 16, 2016

Pegivirus Infection in Domestic Pigs Germany Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC

Pegivirus Infection in Domestic Pigs Germany Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC


Pegivirus Infection in Domestic Pigs, Germany - Volume 22, Number 7—July 2016 - Emerging Infectious Disease journal - CDC



Volume 22, Number 7—July 2016

Letter

Pegivirus Infection in Domestic Pigs, Germany

On This Page

  • Letter
  • Suggested Citation

Figures

  • Figure

Technical Appendicies

  • Technical Appendix

Downloads

  • PDF[504 KB - 3 pgs]
  • RIS[TXT - 2 KB]
Suggested citation for this article
To the Editor: The family Flaviviridae includes many human and animal virus pathogens. Recently, in addition to the genera Flavivirus, Hepacivirus, and Pestivirus, a fourth genus, Pegivirus, has been identified (1). In addition to human pegiviruses, a range of phylogenetic, highly divergent pegiviral sequences have been identified in various animal species, including primates, bats, rodents, and horses (2). We report the detection of a porcine pegivirus (PPgV) in serum samples from pigs.
Initially, we investigated pooled serum samples by using high-throughput sequencing methods and isolated RNA from individual porcine serum samples by using the QIAmp Viral RNA Mini Kit (QIAGEN, Hilden, Germany). We prepared libraries compatible with Illumina (San Diego, CA, USA) sequencing from pooled samples and individual serum samples by using the ScriptSeq version 2 RNA-Seq Library Preparation Kit (Epicenter, Madison, WI, USA) and sequenced them by using a HiSeq 2500 (2 × 150 cycles paired-end; Illumina) for pooled samples and MiSeq (2 × 250 cycles paired-end; Illumina) for individual samples (3).
We conducted quantitative reverse transcription PCR (RT-PCR) by using a Quantitect-SYBR Green Assay (QIAGEN) and primers PPgV_fwd: 5?-CTGTCTATGCTGGTCACGGA-3? and PPgV_rev: 5?-GCCATAGAACGGGAAGTCGC-3?. By using high-throughput sequencing of the pooled serum sample library (23,167,090 reads), we identified 1 contig (4,582 bp) that had distant nucleotide sequence simi-larity to bat pegivirus (69% and 4% sequence coverage) and 2 contigs (2,683 bp and 665 bp) that had 73% sequence coverage, thereby covering 8% and 37% of the identified sequence. RT-PCR with primers designed on basis of recovered sequences identified the sample containing pegivirus sequences. Subsequent MiSeq analysis (7,085,595 reads) of an RNA library prepared from a sample from 1 animal identified 1 contig (9,145 nt) with sequence similarity to pe-givirus sequences.
We performed 3? end completion of the viral genome by rapid amplification of cDNA ends and identified the entire open reading frame of PPgV_903 encoding 2,972 aa (GenBank accession no. KU351669). Analysis of the pegivirus 5?-untranslated region identified a highly structured internal ribosome entry site motif (Technical Appendix[PDF - 302 KB - 5 pages]), which was similar in structure to previously described 5? untranslated region structures of other pegiviruses (4,5).
Pegiviruses do not encode a protein homologous to the capsid protein of other viruses of the family Flaviviridae, another common feature of pegiviruses (6). The presence of cleavage sites for cellular signal peptidases and viral proteases indicates that, similar to polyproteins of other pegiviruses and members of the genus Hepacivirus, the pegivirus polyprotein NH2-E1- E2-Px-NS2-NS3-NS4A-NS4B-NS5A-NS5B-COOH (E [envelope], NS [nonstructural], and Px [protein X]) is cleaved co-translationally and posttranslationally.
We tested 3 additional animals from the same breeding cohort for virus RNA at irregular intervals for 22 months. One animal was positive for pegivirus RNA for 7 months, and the other 2 animals had pegivirus RNA in serum for 16 and 22 months. None of these animals showed obvious clinical signs attributable to virus infection. Follow-up investigation of 455 serum samples from 37 swine holdings from Germany identified 10 (2.2%) samples from 6 pig holdings that contained pegivirus RNA. We obtained 2 additional near full-length genomic sequences (PPgV_80F and PPgV_S8-7) from 2 animals in different herds by high-throughput sequencing, RT-PCR, and Sanger sequencing (GenBank accession nos. KU351670 and KU351671).
Thumbnail of Phylogenetic analyses of human and animal pegiviruses, Germany. We constructed a maximum-likelihood tree on the basis of the complete coding region and used the general time reversible model for modeling of substitutions. Bootstrap analysis was performed with 200 replicates. Numbers along branches are percentage bootstrap values. GenBank accession numbers are in parentheses. Arrow indicates strain isolated in this study. Scale bar indicates nucleotide substitutions per site. BPgV, b
Figure. Phylogenetic analysis of human and animal pegiviruses. We constructed a maximum-likelihood tree on the basis of the complete coding region and used the general time reversible model for modeling of substitutions....
Phylogenetic analyses of complete coding regions showed the close relationship of the 3 pegivirus sequences from Germany. These 3 sequences formed a separate clade within the genus Pegivirus (Figure). Pairwise comparison between PPgV_903 and the other 2 pegivirus sequences showed strong nucleotide identities (96.0%–98.4%). A distance scan over the entire polyprotein showed genetic distance to other pegiviruses and demonstrated that NS3 and NS5B contain the most conserved regions among pegivirus polyproteins (Technical Appendix[PDF - 302 KB - 5 pages]).
In horses, 2 distinct pegiviruses that had different potentials to cause clinical disease in infected animals have been described (4,7). No obvious clinical effects were observed in pegivirus-infected animals during our study. However, potential consequences of viral infection for animal health and food production need to be explored more closely under field and experimental conditions. Pegiviruses can interact with the immune system of the host. Co-infection with human pegivirus and HIV can have beneficial effects, which result in decreased retroviral loads and delayed disease progression (8).
It will be useful to investigate whether co-infections with pegiviruses can influence clinical manifestations of infectious diseases of swine, including multifactorial diseases such as postweaning multisystemic wasting syndrome, in which unknown immune modulating virus infections have been suggested to influence the degree of clinical illness (9). RNA viruses have considerable potential to adapt to new environmental conditions and to overcome host restrictions (10). Until now, the host tropism of PPgV has not been investigated in detail. Therefore, additional studies will be required to elucidate whether the spectrum of potential hosts might include other farm or companion animals, and whether the virus might be able to infect humans.
Christine Baechlein1, Adam Grundhoff1, Nicole Fischer, Malik Alawi, Doris Hoeltig, Karl-Heinz Waldmann, and Paul BecherComments to Author 
Author affiliations: University of Veterinary Medicine Hannover, Hannover, Germany (C. Baechlein, D. Hoeltig, K.-H. Waldmann, P. Becher); German Center for Infection Research Partner Site Hannover–Braunschweig, Hannover (C. Baechlein, P. Becher); German Center for Infection Research Partner Site Hamburg–Lübeck–Borstel, Hamburg (N. Fischer, A. Grundhoff); Heinrich Pette Institute, Hamburg, Germany (A. Grundhoff, M. Alawi); University Medical Center Hamburg–Eppendorf, Hamburg (N. Fischer, M. Alawi)

Acknowledgments

We thank Jens Böttcher, Thomas Große Beilage, Diana Meemken, Alexandra von Altrock, and Cornelia Schwennen for collecting serum samples; Polina Parfentev for providing excellent technical assistance; and Daniela Indenbirken for providing support in preparation of the RNA library.
This study was supported by the German Center for Infection Research/Thematic Translational Unit Emerging Infections.

References

  1. Stapleton JT, Bukh J, Muerhoff AS, Foung S, Simmonds P. Assignment of human, simian and bat pegiviruses (previously described as GBV-A, GBV-C, and GBV-D) as members of a new genus (Pegivirus) within the Flaviviridae [cited 2015 Oct 21]. http://www.ictvonline.org/proposals/2012.011a-dV.A.v2.Pegivirus.pdf
  2. Thézé J, Lowes S, Parker J, Pybus OG. Evolutionary and phylogenetic analysis of the hepaciviruses and pegiviruses. Genome Biol Evol.2015;7:2996–3008 .DOIPubMed
  3. Baechlein C, Fischer N, Grundhoff A, Alawi M, Indenbirken D, Postel A, Identification of a novel hepacivirus in domestic cattle from Germany. J Virol.2015;89:7007–15. DOIPubMed
  4. Kapoor A, Simmonds P, Cullen JM, Scheel TK, Medina JL, Giannitti F, Identification of a pegivirus (GB virus-like virus) that infects horses. J Virol.2013;87:7185–90. DOIPubMed
  5. Simons JN, Desai SM, Schultz DE, Lemon SM, Mushahwar IK. Translation initiation in GB viruses A and C: evidence for internal ribosome entry and implications for genome organization. J Virol. 1996;70:6126–35.PubMed
  6. Stapleton JT, Foung S, Muerhoff AS, Bukh J, Simmonds P. The GB viruses: a review and proposed classification of GBV-A, GBV-C (HGV), and GBV-D in genus Pegivirus within the family Flaviviridae. J Gen Virol. 2011;92:233–46 .DOIPubMed
  7. Chandriani S, Skewes-Cox P, Zhong W, Ganem DE, Divers TJ, Blaricum AJ, Identification of a previously undescribed divergent virus from theFlaviviridae family in an outbreak of equine serum hepatitis. Proc Natl Acad Sci U S A. 2013;110:E1407–15. DOIPubMed
  8. Schwarze-Zander C, Blackard JT, Rockstroh JK. Role of GB virus C in modulating HIV disease. Expert Rev Anti Infect Ther. 2012;10:563–72 .DOIPubMed
  9. Grau-Roma L, Fraile L, Segalés J. Recent advances in the epidemiology, diagnosis and control of diseases caused by porcine circovirus type 2. Vet J.2011;187:23–32. DOIPubMed
  10. Rosenberg R. Detecting the emergence of novel, zoonotic viruses pathogenic to humans. Cell Mol Life Sci. 2015;72:1115–25. DOIPubMed

Figure

  • Figure. Phylogenetic analysis of human and animal pegiviruses. We constructed a maximum-likelihood tree on the basis of the complete coding region and used the general time reversible model for modeling of...

Technical Appendix

  • Technical Appendix. Additional information on pegivirus infection in domestic pigs, Germany.  302 KB
Suggested citation for this article: Baechlein C, Grundhoff A, Fischer N, Alawi M, Hoeltig D, Waldmann K-H, et al. Pegivirus infection in domestic pigs, Germany [letter]. Emerg Infect Dis. 2016 Jul [date cited]. http://dx.doi.org/10.3201/eid2207.160024
DOI: 10.3201/eid2207.160024
download now

Read more »

Monday, August 29, 2016

Confirming Legionnaires’ Disease Outbreak by Genome Based Method Germany 2012 Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC

Confirming Legionnaires’ Disease Outbreak by Genome Based Method Germany 2012 Volume 22 Number 7—July 2016 Emerging Infectious Disease journal CDC


Confirming Legionnaires’ Disease Outbreak by Genome-Based Method, Germany, 2012 - Volume 22, Number 7—July 2016 - Emerging Infectious Disease journal - CDC



Volume 22, Number 7—July 2016

Letter

Confirming Legionnaires’ Disease Outbreak by Genome-Based Method, Germany, 2012

On This Page

  • Letter
  • Suggested Citation

Figures

  • Figure

Downloads

  • PDF[1.24 MB - 2 pgs]
  • RIS[TXT - 2 KB]
Suggested citation for this article
To the Editor: We report an outbreak of Legionnaires’ disease in southwestern Germany. On July 31, 2012, the State Health Agency of Rhineland-Palatinate was informed by the local health department of the city of Zweibrücken that 10 patients tested positive for Legionella pneumophila, the bacterium that causes Legionnaires’ disease. The onset of disease for all case-patients was from June 26 through July 25, which exceeded the yearly average of 1–4 patients a month. By August 23, we had received notifications of 19 patients with pneumonia and notification of 1 patient who did not exhibit pneumonia. We set 3 parameters for reporting a patient as a Legionnaires’ disease case-patient. First, the patient had to either live in or have been visiting the city of Zweibrücken in June 2012 before onset of disease. Second, the respiratory samples from the patient had to contain L. pneumophila or the results of patient’s serogroup 1 urinary antigen test had to be positive for the bacterium (1). Finally, clinical or radiologic confirmation of the disease was required. Of 20 patients who fit the case definition, 14 were male and 6 were female. Nine smoked and 2 were immunocompromised; none died.
All case-patients were positive for L. pneumophila serogroup 1 urinary antigen. From clinical samples of 2 patients, legionellae were cultured, and the infecting strain was confirmed as L. pneumophila serogroup 1, monoclonal subgroup Allentown-France, sequence type (ST) 82 (2,3). Currently, 118 strains of this ST are found in the European database for sequence-based typing of L. pneumophila (2). Most ST82 strains were isolated from clinical samples; thus, this ST appears more likely than other strains to infect humans. Further, 3 respiratory samples from case-patients were positive in a PCR for L. pneumophila serogroup 1 (4) but were negative by culture. These samples were investigated with the nested sequence-based typing protocol, which allows typing data to be obtained directly from clinical samples (2). Of the 3 samples, 2 were confirmed as ST82.
The local health authority did not initially identify likely sources of transmission such as cooling towers, public spas, or warm water supply systems in the vicinity of the patients (5). Environmental samples were taken from the homes of 15 of the 20 patients; all samples tested negative for Legionella (6).
Thumbnail of Geographic distribution of cooling tower and home and work addresses (n = 23) of patients; 1 patient may be represented twice with home and work address, because place of infection is unknown. The addresses marked “immobile” belong to 2 patients who had not left their homes. Two samples had undergone core genome multilocus sequence typing (cgMLST), and sequence type (ST) 82 was typed (represented by 2 home addresses and 1 work address). For 2 samples, only ST82 was typed. Two dots i
Figure. Geographic distribution of cooling tower and home and work addresses (n = 23) of patients; 1 patient may be represented twice with home and work address, because place of infection is...
To find the source of the outbreak, we plotted 20 home and 7 work addresses of patients using Quantum-GIS software (7) and found that 18 addresses were within a 2-km radius of each other, including 2 patients who had limited mobility and had not left their homes during their incubation period (Figure). We conducted a site visit on August 22 to inspect a sewage plant and 2 large manufacturing plants (A and B) that were within the same 2-km radius. Neither the sewage plant nor plant A had a potential Legionella source. Plant B had a cooling tower mounted on a rooftop that was described by the company as a closed circuit cooling system, indicating that no aerosols would be released, and thus was missed by the initial local health department inquiry. However, closed circuit referred only to the primary cooling circuitry, whereas excess heat was exchanged through wet surface cooling, allowing release of aerosols into the atmosphere. The local health department immediately shut down the cooling tower, and plant B used shot-dose chlorine to disinfect it. Before disinfection, we obtained 3 swab specimens and 250-mL samples of water from the reservoir and plated them in dilutions with and without acid wash (6,8). Samples without acid wash were completely overgrown, whereas a single 1-mL sample with acid wash showed 20 Legionella colonies after 7 days. Three colonies were typed and found to belong to the epidemic strain. Of the 27 work and home addresses, 6 were within a 1-km radius of the cooling tower, and 18 were within a 4-km radius (Figure). No further cases occurred within the incubation period (up to 14 days after closure of the cooling tower).
To further confirm this cooling tower as the source of the outbreak, we applied core genome multilocus sequence typing (cgMLST) (3). We analyzed allelic differences of 1,521 gene targets of the core genome of L. pneumophila using the pairwise ignore missing values option in SeqSphere+ software (Ridom GmbH, Münster, Germany). Results showed that the strains from 2 patients with culture-positive test results and the 3 environmental ST82 strains were identical in their cgMLST profile, which covers 47% of the Philadelphia-1 reference genome.
Currently, no German law requires a registry for cooling towers; such a registry would accelerate identification of potential L. pneumophila emission during outbreaks (9). In January 2015, a code of conduct for maintenance of cooling towers went into effect (10). Modern typing methods such as cgMLST can serve as supporting tools in confirming infection origin. However, this method must be validated on a larger scale, and its discriminatory power compared with that of current typing methods. Further cgMLST studies with other ST82 strains are underway.
Florian BurckhardtComments to Author , Andre Brion, Jeanette Lahm, Heinz-Ulrich Koch, Karola Prior, Markus Petzold, Dag Harmsen, and Christian Lück
Author affiliations: Federal State Agency for Consumer & Health Protection Rhineland-Palatinate, Landau, Germany (F. Burckhardt, A. Brion); Local Health Authority Südwestpfalz, Pirmasens, Germany (J. Lahm, H.-U. Koch); University of Münster, Münster, Germany (K. Prior, D. Harmsen); Dresden University of Technology, Dresden, Germany (M. Petzold, C. Lück)

Acknowledgments

We acknowledge the support of Jürgen Blanz of the Regional Trade Control, Rhineland Palatinate, and thank the visited companies for their full and unconditional cooperation. We also acknowledge the contribution of all those individuals involved in the outbreak—local, regional and national Health Protection Agency staff, the Local Authority, the Health and Safety Executive, Environmental Health Officers, hospital staff and microbiologists —for their dedication and professionalism in the face of the outbreak.
This work received financial support from the Robert Koch Institute (BMG/RKI 1369-464).

References

  1. European Center for Disease Control. Stockholm, Sweden. Case definitions for Legionnaires’ disease: 2014 [cited 2016 Apr 29].http://www.ecdc.europa.eu/en/activities/surveillance/ELDSNet/Pages/EU%20case%20definition.aspx
  2. European Study Group for. Legionella Infections (ESGLI). The EWGLI SBT database for the typing of Legionella pneumophila: 2015 [cited 2016 Apr 29]. http://www.hpa-bioinformatics.org.uk/legionella/legionella_sbt/php/sbt_homepage.php
  3. Moran-Gilad J, Prior K, Yakunin E, Harrison TG, Underwood A, Lazarovitch T, Design and application of a core genome multilocus sequence typing scheme for investigation of Legionnaires’ disease incidents. Euro Surveill. 2015;20:21186. DOIPubMed
  4. Mérault N, Rusniok C, Jarraud S, Gomez-Valero L, Cazalet C, Marin M, Specific real-time PCR for simultaneous detection and identification ofLegionella pneumophila serogroup 1 in water and clinical samples. Appl Environ Microbiol. 2011;77:1708–17. DOIPubMed
  5. Mercante JW, Winchell JM. Current and emerging Legionella diagnostics for laboratory and outbreak investigations. Clin Microbiol Rev.2015;28:95–133. DOIPubMed
  6. International Standardisation Organisation. ISO 11731. Water quality—detection and enumeration of Legionella. International Standardisation Organisation; 1998 [cited 2016 Apr 29]. http://www.iso.org/iso/catalogue_detail?csnumber=19653
  7. Quantum Geographic Information System Team (QGDT). Open Source Geospatial Foundation Project, 2012 [cited 2016 Mar 27].http://qgis.osgeo.org
  8. Deutsche Industrie Norm. EN ISO 11731–2. Water quality—detection and enumeration of Legionella. Part 2: direct membrane filtration method for waters with low bacterial counts. Deutsche Industrie Norm, Berlin; 2008 [cited 2016 Apr 29]. http://www.beuth.de/de/norm/din-en-iso-11731-2/107294968
  9. Maisa A, Brockmann A, Renken F, Luck C, Pleischl S, Exner M, Epidemiological investigation and case-control study: a Legionnaires’ disease outbreak associated with cooling towers in Warstein, Germany, August–September 2013. Euro Surveill. 2015;20:30064. DOIPubMed
  10. Verein Deutscher Ingenieure. Securing hygienically sound operation of evaporative cooling systems (VDI Cooling Tower Code of Practice). Verein Deutscher Ingenieure, Berlin; 2015 [cited 2016 Apr 29]. http://www.beuth.de/de/technische-regel/vdi-2047-blatt-2/224206933

Figure

  • Figure. Geographic distribution of cooling tower and home and work addresses (n = 23) of patients; 1 patient may be represented twice with home and work address, because place of infection...
Suggested citation for this article: Burckhardt F, Brion A, Lahm J, Koch HL, Prior K, Petzold M, et al. Confirming Legionnaires’ disease outbreak by genome-based method, Germany, 2012. Emerg Infect Dis. 2016 Jul [date cited]. http://dx.doi.org/10.3201/eid2207.151738


DOI: 10.3201/eid2207.151738

download now

Read more »